There are different names for the pipes commonly used to discharge foul and storm water from buildings, namely;
  1. Private drain - a drain serving a single premises.
  2. Private sewer - a drain serving two or more premises.
  3. Public sewer - a drain serving two or more premises owned or adopted by the sewerage undertaker (Severn Trent Water Limited).
The vast majority of private drains and sewers in the normal circumstance will discharge into a public sewer, in certain circumstances what might initially appear to be a private sewer may in fact be a public sewer.
 
A public sewer is a sewer which is vested in a sewerage undertaker, within the Borough of Oadby & Wigston this is Severn Trent Water Limited.
 
The majority of public sewers run under public roads, however in some instances they can be found to cross private land. If the sewer to your property was built before October 1937 then it is also considered to be a public sewer under the provisions of Section 24, of the Public Health Act 1936.
 
If you think that the sewer serving your home might be a Section 24 or adopted public sewer then you should clarify the matter with Severn Trent Water Limited who will be able to supply you with a definitive answer.
 

The Requirement 

When builing over or within 3 metres of a public sewer the Approved Document to Regulation H4 (Building Over Sewers) of the Building Regulations 2000 makes it clear that;
  • You must consult with the sewerage undertaker.
  • Adequate provision is to be made to prevent any undue risk to the building in the event of a failure of a drain or sewer.
  • Access to the drain or sewer must be maintained externally to any building or extension at all times.
  • The drain or sewer must be adequatly protected during construction.
  • Adequate provision is to be made for the protection of a drain or sewer from any settlement.

For further clarification on these items you should refer to Approved Document H of the Building Regualtions 2000, a copy of this can be viewed via the Planning Portal web site|.

 

Building Regulations Submission

Making a Building Regulation Submission where building over or within 3 meters of a public sewer up to 225 millimetres in diameter will require a Full Plans Submission| under the regulations, a Building Notice cannot be accepted in these circumstances.

 

As part of the process building control will establish from Severn Trent Water Limited that you have obtained their consent and agreement to the works, to be able to issue an approval under the building regulations.

 

How to see if a public sewer is affected

Information on the siting of the public sewers can be obtained from Severn Trent Waters records management centre by telephoning them on 0121 452 3306. A copy is also available at the council offices and is available for inspection upon request however copies or photographs of these cannot be taken and these are not as concise as the records held by Severn Trent.
 
If a public sewer could be affected by proposed building works, it is advisable to obtain consent from Severn Trent Water before making a building regulations application, this will avoid delay in the full plans approval process.
 